3.0 Three significant figures.
3.5 Three significant figures plus a fourth figure rounded to either 0 or 5.
Table 3. Example values displayed using each of the three significant figure options.
To change the number of Significant Figures
1. Press [Setup] to access the Setup menu.
2. Press [] or [] to select "Sig Figs" in the list.
3. Press [] or [] to select 2.5, 3.0, or 3.5.
5.2 Device Setup
The DM-2 mark II supports fan equipment from virtually every other calibrated fan manufacturer on
the market.
Table 4. List of compatible devices to be used with the DM-2.
Model 200 fan, Q32 DucTester
Model 1000 systems with 0.75 hp yellow wheel rim style fans
Model Q46 and Q56 systems with 0.75 hp yellow foam core fan
Older Model Q4E, Q5E and QMG systems with 2 hp yellow foam
core Door Fan
Model Q4E, Q5E and QMG systems with 2 hp yellow foam core
Door Fan – all fans are self-referencing (have green tube)
0.75 hp black wheel rim style fan
Exhaust Fan Flow Meter – measures air flow through residential
exhaust fans between 10 and 124 CFM
True Flow Grid – measures flow through a residential air handler
0.75 hp black wheel rim style fan