Tubing Accessory Kit
35 ft (10 m) of blue, red, yellow and green 1/4 inch
(12mm) outside diameter tubing. Static Pressure
Probe, 4 inch (100 mm) x 1/8 inch (6 mm) outside
diameter metal probe, 2 T and 2 male-to-male con-
nectors. Red L for duct leakage to outdoors test.
Part #: TU119
Flow Hood
24 x 24 inches
(61 x 61 cm)
Part #: PP105
Page 8 of 8
Optional accessories
12.5ft (3.8m)
Flex Duct for
DucTester
Part #: DU161
Flange
to connect
Flex Duct to
register
Part #: DU157
Verication
Plate
Part #: DU159
Deluxe Cordura Toolbag with
Shoulder Strap
Part #: TL118
Grill Mask 12in x 216ft,
12in perfs,
Hi-stick White,
Single Roll
Part #: GR116
Part #: GR117 (for case of 3)
Umbilical for
DucTester
fans, 7ft (2 m)
Part #: DM240
Optional DU159 Verication
Plate shown.
Tape the optional ow
Verication Plate to the
Flange and attach the
red tube.
Attach the Flex Duct to the
exhaust side of the fan
to pressurize the Flex Duct.
Stretch the Flex Duct to
it’s full length.
Set the DM-2 to measure
“Flow” in “CFM @25 Pa”.
Adjust the speed until
“PrA” reads close to 25 Pa.
Read the Verication
Plate to determine the
acceptable range for ow.
Typically, 100 to 110 CFM
is a pass.
Check gauge operation and check for blocked, leaking or
pinched tubes weekly, and anytime results are in question.
To perform the gauge check, you will need the gauge
and Umbilical.
Press [Exit] [Time Average] until “4s” appears.
Press [Mode] repeatedly to display “PrB”.
Connect the yellow tube between the red and
yellow ports.
Repeat between different ports with each of the
tubes you use for testing.
Field check gauge weekly
If readings on “PrA” and “PrB” are within 2% and
don’t drop rapidly, the tube is not blocked or
leaking and the gauge is correct.
Checking your gauge
and tubes regularly will
eliminate a common
source of error in
readings.
Mid-Range Ring
& Low-Range
Ring
(Mid) Part #: DU154
(Low) Part #: DU155
Check the DucTester system monthly with a
known setup―if flow is outside the acceptable
range then system needs full calibration.
Field check system monthly