Enable and Disable Flow Range Configurations
It is also possible to enable and disable Flow Ranges for each of the devices being used. This will
eliminate the need to scroll through each Flow Range when it can be determined which ones are the
most well-used, cutting down on gauge setup time. Disabled Flow Ranges are saved in system memory,
but can always be enabled if necessary.
Table 5. DM-2 compatible devices and associated Flow Range configurations.
Calibrated Fan
Available Flow Ranges
Retrotec 600/700
Open, 12, 8, 6, 2, 1
Retrotec 800/900
18F, 18R, 9, 5, 3, 1.4, 1.3, 1.2, 1.1, 0.1
Retrotec 1000
Open, A, B, C8, C6, C4, C2
Retrotec /2000/3000/3000SR
Open, A, B, C8, C6, C4, C3, C2, C1, L4, L2, L1
Retrotec DU100/DU200
Open, Mid, Low
Minneapolis DuctBlaster B
Open, Ring 1, Ring 2, Ring 3
Minneapolis Model 3/4
Open, A, B, C, D, E
Minneapolis Exhaust Fan
E1, E2, E3
Minneapolis True Flow
#14, #22
Infiltec E3
Open, 7 Holes, 4 Holes, 3 Holes, 2 Holes, 1 Hole
To enable/disable Flow Range configurations in Device [Setup]
1. Enter the Device Setup menu by pressing [Enter] on “Device Setup”.
2. Select the device on which Flow Ranges need to be enabled/disabled and press [Enter].
3. Press [] or [] arrows to turn the Flow Ranges on ("Yes") or off ("No").