Page 9 of 66
©Retrotec Inc. 2012
2 DM-2 Digital Gauge Basics
The DM-2 is Retrotec’s digital micromanometer. It combines simple but comprehensive functionality,
with intuitive controls and setup. The DM-2 is a dual channel digital micromanometer that always
displays a pressure on Channel A, but will display pressure, flow,
velocity, or leakage area on Channel B (depending on the Mode
selected). To ensure accurate results, the DM-2 takes up to four
pressure readings per second on each channel, and updates the
information displayed on the screen every second.
2.1 Batteries
The DM-2 can draw power from an AC power supply through the fan,
directly from the wall outlet, or from four AA batteries. It is
recommended that the gauge be used on battery power when possible.
When battery power is insufficient to power the gauge, the warning
message "Battery Too Low" will appear on the screen.
The DM-2 includes the ability to recharge the batteries inside the gauge. The batteries will not start
charging if the DM-2 is not turned on first (i.e. you must turn on the DM-2 first, and then plug in the AC
power supply to charge the batteries).
To prolong battery life, recharge the batteries only when they reach ¼ power
(displayed on the battery status indicator). Do not operate the DM-2 with the
AC power adapter or the Umbilical power cord attached after they are fully
charged; this will significantly shorten the lifespan of rechargeable batteries. If the DM-2 must be
operated with AC power, remove the batteries to prevent the shortening of the battery lifespan. The
batteries are fully charged when the battery indicator is solid black. Allow the batteries to occasionally
discharge completely to improve battery life.
Install batteries
The DM-2 comes with four AA NiMH rechargeable batteries. The batteries can be charged in the DM-2
with the AC power adapter, or in a compatible battery charger. The batteries should be charged for at
least 8 hours each time. To completely charge the batteries, prior to using the gauge for the first time,
24 hours may be required.