Retrotec DM-2A Manual de usuario Pagina 40

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 66
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 39
Page 40 of 66
©Retrotec Inc. 2012
Achieve the Target Pressure (Method 1) Using Set Pressure
1. Press [Set Pressure] and enter the target pressure. The fan should increase in speed and
eventually stabilize with PrA approximately matching the input target pressure.
2. Enter PrA (pressure reading on Channel A, which is the building pressure or also called room
pressure) and PrB (pressure reading on Channel B which is the Fan Pressure) from the DM-2
into CA2001.
Achieve the Target Pressure (Method 2) Using Set Speed
1. Press [Jog/Hold] until Jog appears in the top center of the DM-2 display
2. Press []or [] to increase/decrease the fan speed until PrA approximately matches the
input target pressure. (Quickly press and release for increments of 1% speed. Hold and release
for increments of 5% speed)
3. Enter the PrA (pressure reading on Channel A which is the building pressure or also called
room pressure) and the PrB (pressure reading on Channel B which is the Fan Pressure) from
the DM-2 into CA2001.